HDL Works
SPR | Title | Released | Description |
---|---|---|---|
Device support | 3.2.2 | Improved recognition of Agilex-5 devices | |
2333 | Not all voltage values of AMD Zynq UltraScale pins extracted | 3.2.2 | Voltage values extracted from the ..power_routed.rpt file are not propagated for the power pins of the Processor system. |
2324 | Altium extension fails when project directory is read-only | 3.2.2 | When the Altium PCB directory is readonly the PCB Xml netlist should be placed somewhere else. |
2313 | Not possible to specify license server using IPv6 address on Linux | 3.2.1 | In FlexLM multiple files/servers can be specified in an environment variable. On Unix entries in the environment variable are separator by a colon (:). However an IPv6 address also contains colons and its use resulted in incorrect missing file errors. |
2303 | Wiring Allegro projects fails when spaces are in the directory path | 3.2.1 | The Skill wiring engine cannot cope with spaces in the directory path. |
2283 | Option to remove unplaced components from the netlist | 3.2.1 | Some netlists contain components that should be ignored. They may have DNI (do not instantiate) or DNP (do not place/populate) in their name or properties. |
2277 | Handle components in netlist reduction which are in principle a shortcut | 3.2.1 | 2 pin components like a fuse (F), a Ferrite bead (FB) and a Circuit breaker (CB) are in principle an electrical shortcut with a special function. |
2266 | Default netlist reduction properties | 3.2.1 | It is not possible to set default netlist reduction properties in user preference dialog. |
2262 | Module connection lost after renaming module | 3.2.1 | When renaming a module name in the XML file, its connection is lost. |
2261 | Netlist reduction fails on a series resistor with test point | 3.2.1 | Series resistors are not removed during reduction when one of the nets connected to the resistor contains a
test point component. The TP component can be ignored in reduction (or even be removed). |
2260 | Support for compressed Cadence Packager pstcmdb.dat file | 3.2.1 | The Allegro packaged netlist file 'pstcmd.dat' generated by version 17.2 has become a compressed file. |
2250 | Add a message dialog when opening a project created with an older version | 3.2.1 | To prevent changing/saving a modified project to a newer database format add a message dialog when opening a project using an older database format. Message can be disabled in the user preferences. |
Copyright © 2004 - 2024 HDL Works